top of page

WELL-KLEAN© · WATER WELL REHABILITATION

Your well isn't worn out. It's plugged.

Most lost capacity is biofilm and mineral scale, not structural failure. The Well-Klean© program removes both with proprietary, corrosion-inhibited chemistry sized to each well's own data, then proves the recovery with a pumping test. Wells come back, and they stay back.

Formulated in-house · treatment plans built from analytical data · spent solution neutralized on site and disposed of under local, state and federal requirements.

WHY OPERATORS SWITCH

The numbers behind Well-Klean©.

Chlorine, straight acid, and brushing treat what you can see. Well-Klean© removes the biofilm and the scale it protects, which is why the capacity you recover holds.

91%

 

Of original 1990 rating recovered

 

Thomas Well No. 5: 2,090 gpm and 27.87 gpm/ft after Well-Klean© (HCT write-up).

 

9 of 10

 

Declining wells HCT assesses are biofouled

 

Biofilm, not structural failure, is the usual cause in HCT's data.

 

10–30%

 

Of system water volume: typical Descaler dose

 

Set per well from the label and the well's own data.

 

12 hrs

 

To dissolve mineral scale

 

Descaler works downhole in a single soak period.

 

WHAT IS ACTUALLY PLUGGING YOUR WELL

In HCT's assessments, nine out of ten declining wells are biofouled, not broken.

Iron and sulfur bacteria colonize the screen and gravel pack and build a polysaccharide biofilm. That slime traps sand, silt, and mineral scale, and shields the colony from chlorine. Every year the flow path narrows a little more, and the well is written off as "tired" when it is really plugged.

 

Well-Klean© starts from the well's own water and deposit analysis, so the chemistry goes after what is actually in the hole: carbonate, iron oxide, manganese, silicate, and the biofilm holding it all together.

Fouled well casing with iron oxide (rust) and mineral scale buildup before Well-Klean treatment

Fouled pump column and casing before treatment: biofilm-bound iron and mineral scale that brushing alone cannot remove.

THE WELL-KLEAN© PROGRAM

Assess. Plan. Treat. Verify.

Well-Klean© is a structured rehabilitation program, not a drum of chemical. HCT builds each protocol from the well's analytical data, prescribes the products, rates, soak times, and sequence, and documents the recovery with pumping tests before and after.

01

 

Assess and analyze

 

Water and deposit analysis identify the fouling type, its severity, and the condition of the casing, screen, and gravel pack.

02

 

Plan the treatment

 

A written protocol: products, use rates, soak times, and the chemical and mechanical sequence for this well.

03

 

Treat on site

 

Applied by an authorized Well-Klean© contractor to HCT Best Practices, with HCT support on call.

04

 

Verify the recovery

 

Post-treatment pumping tests against the baseline. The result is a number, not a description.

RESTORED CAPACITY

 

Pumping rates come back

 

Deposits restricting the screen and gravel pack are dissolved, not just knocked loose.

EXTENDED WELL LIFE

 

Rehab instead of replace

 

Proactive treatment protects the casing and defers a new well by years.

LOWER TREATMENT COST

 

Less product, faster jobs

 

Concentrated chemistry cuts gallons, soak time, and rig time on site.

WELL-KLEAN© VS. THE USUAL METHODS

Chlorine, acid, and brushing treat the symptom. Well-Klean© removes the cause.

WHAT MATTERS DOWNHOLE

Penetrates the biofilm / EPS matrix

Dissolves carbonate, iron and silicate scale

Reaches the gravel pack, not just the screen

Corrosion-inhibited for steel, stainless, PVC

Biodegrades to dissolved oxygen and water

Recovery holds without rapid regrowth

CHLORINE

✕

Partial

✕

✕

✕

✕

MECHANICAL

✕

✕

✕

✓

—

✕

WELL-KLEAN©

✓

✓

✓

✓

✓

✓

WELL-KLEAN© PRODUCTS

“Three formulations. Every kind of fouling.”

DESCALER (PRE-BLEND)

 

Mineral scale and metal oxides

 

A concentrated, corrosion-inhibited acid solution for carbonate, iron, manganese, and silicate scale. Inhibited for extended downhole soak periods; corrosive to skin and eyes — handle per the SDS.

 

12 hrs

dissolves scale within

 

Product details →

WATERSOLV™ BC

 

Biofilm and bacteria

 

Peroxide-based bioremediation that breaks down the biofilm matrix and oxidizes the bacteria within it. Corrosion-inhibited, and it biodegrades to dissolved oxygen and water.

 

O₂ + H₂O

what BC breaks down into

 

Product details →

CONCENTRATE

 

Protection for compromised casings

 

Proprietary base chemistry that adds corrosion inhibition and works as a surfactant and sequestering agent where the casing needs protecting.

 

3 jobs

inhibitor · surfactant · sequestrant

PROVEN RESULTS · THOMAS WELL NO. 5

“From pumping off at 270 gpm to 2,090 gpm on the same well.”

BEFORE WELL-KLEAN©

 

Before rehabilitation

 

After a plug-back to 987 ft the well pumped off at about 270 gpm with the pumping level at 690 ft — a candidate for replacement.

 

270 gpm

at 690 ft · 1.19 gpm/ft specific capacity

 

Case studies →

AFTER WELL-KLEAN©

 

Documented recovery

 

After two months of pumping and development the well was turned over at 2,090 gpm with the pumping level at 558 ft, on the original casing.

 

2,090 gpm

at 558 ft · 27.87 gpm/ft specific capacity

 

Case studies →

THE DIFFERENCE

 

Documented, not described

 

Pre- and post-treatment pumping tests on every Well-Klean© job, so the result is a number you can put in front of a board or a bank.

 

91%

of the well's original 1990 rating

FROM OUR DEALER NETWORK

Hear it from Alpha Southwest.

Alpha Southwest is one of HCT's authorized Well-Klean© dealers. In this testimonial they walk through why they run the program on their customers' wells and what it has done for the results they can promise.

 

Every Well-Klean© dealer is trained and supported directly by HCT and treats wells to the same written protocol, so the outcome does not depend on who is holding the hose.

Watch: Alpha Southwest, authorized Well-Klean© dealer, on running the program in the field.

GO DEEPER

Learn the science before you pick a contractor.

Everything HCT knows about why wells foul and how to bring them back is published here. Open the topic that matches your well.

TOPIC 01

 

Scale dissolution

 

How carbonate, iron, manganese, and silicate scale form downhole and how Well-Klean© Descaler takes them back into solution.

 

Explore topic →

TOPIC 02

 

Biofilms and polysaccharide scale

 

The bacterial slime that binds deposits to your screen and gravel pack, and why disinfection alone falls short.

 

Explore topic →

TOPIC 03

 

Chlorine vs. WaterSOLV™ BC

 

A side-by-side on disinfection versus bioremediation: what each one does to the colony, the deposit, and the casing.

 

Explore topic →

TOPIC 04

 

Well-Klean© processes

 

The step-by-step rehabilitation sequence HCT prescribes, and why it delivers predictable, long-lasting results.

 

Explore topic →

TOPIC 05

 

Best practices

 

HCT's recommended protocols for application, soak times, agitation, and neutralization on site.

 

Explore topic →

TOPIC 06

 

Well tools

 

The brushes, discs, and tooling authorized contractors use alongside the chemistry to work the full casing diameter.

 

Explore topic →

TOPIC 07

 

Case studies

 

Documented rehabilitations with pre- and post-treatment pumping data, including Thomas Well No. 5.

 

Explore topic →

TOPIC 08

 

Well-Klean© products

 

Descaler, WaterSOLV™ BC, and Concentrate: what each does, use rates, and ordering.

 

Explore topic →

TOPIC 09

 

Corps of Engineers

 

A U.S. Army Corps of Engineers technical reference on industrial biocides, shared by HCT as background reading.

 

Explore topic →

READY TO GET STARTED?

Your well has more to give.

Whether you manage a single well or an entire system, start with your well log and water analysis. HCT will tell you what is fouling the well, what it will take to recover it, and who in our dealer network can do the work.

KEEP LEARNING

HCT, LLC · Well-Klean© Water Well Rehabilitation · Scottsdale, Arizona

bottom of page